| XLPE
Insulated L T Power Cables- 600
/ 1000 V as per BS : 5467, IEC : 60502 (I) - TECHNICAL DATA |
STRANDED COPPER &
ALUMINIUM CONDUCTOR SINGLE CORE CABLES
XLPE Insulated Armoured
PVC Sheathed Cable - 600 / 1000V to BS : 5467 & IEC :502(I) |
Nominal Area of Conductor
Sq.mm |
Thickness of XLPE Insulation
mm |
Cable Diameter Overall
mm |
Cable Weight Aluminium
Kg/Km |
Cable Weight Copper
Kg/Km |
Diameter Under Armour
mm |
Armour @ Wire Diameter
mm |
Cable Diameter Overall
mm |
Cable Weight Aluminium
Kg/Km |
Cable Weight Copper
Kg/Km |
50 |
1.0 |
14.2 |
250 |
540 |
12.6 |
1.6* |
18.4 |
460 |
800 |
70 |
1.1 |
16.2 |
330 |
760 |
14.5 |
1.6* |
20.2 |
560 |
900 |
95 |
1.1 |
18.3 |
430 |
1020 |
16.4 |
1.6* |
22.3 |
690 |
1280 |
120 |
1.2 |
20.2 |
510 |
1270 |
18.0 |
1.6* |
24.2 |
800 |
1550 |
150 |
1.4 |
22.4 |
630 |
1560 |
19.8 |
1.6 |
27.4 |
970 |
1600 |
185 |
1.6 |
24.7 |
760 |
1930 |
22.0 |
1.6 |
30.0 |
1150 |
2320 |
240 |
1.7 |
27.7 |
970 |
2510 |
24.6 |
1.6 |
32.8 |
1380 |
2930 |
300 |
1.8 |
30.6 |
1190 |
3120 |
27.3 |
1.6 |
35.6 |
1640 |
3580 |
400 |
2.0 |
34.2 |
1500 |
3970 |
31.2 |
2.0 |
40.5 |
2130 |
4600 |
500 |
2.2 |
38.0 |
1900 |
4980 |
36.0 |
2.0 |
44.2 |
2610 |
5680 |
630 |
2.4 |
42.9 |
2420 |
6400 |
40.0 |
2.0 |
48.8 |
3180 |
7160 |
800 |
2.6 |
47.8 |
3120 |
8210 |
45.0 |
2.5 |
55.4 |
4230 |
9315 |
1000 |
2.8 |
53.0 |
3780 |
10275 |
50.8 |
2.5 |
60.6 |
5000 |
11460 |
|
STRANDED
COPPER & ALUMINIUM CONDUCTOR TWO CORE CABLES
XLPE Insulated Armoured
PVC Sheathed Cable - 600 / 1000V to BS : 5467 & IEC :502(I) |
Nominal Area of Conductor Sq.mm |
Thickness of XLPE Insulationmm |
Cable Diameter Overallmm |
Cable Weight AluminiumKg/Km |
Cable Weight CopperKg/Km |
Diameter Under Armourmm |
Armour @ Wire Diametermm |
Cable Diameter Overallmm |
Cable Weight AluminiumKg/Km |
Cable Weight CopperKg/Km |
16 |
0.7 |
17.0 |
-- |
475 |
15.2 |
1.25 |
20.4 |
--- |
900 |
25 |
0.9 |
20.2 |
415 |
740 |
18.5 |
1.25 |
24.1 |
915 |
1240 |
35 |
0.9 |
22.5 |
480 |
955 |
21.5 |
1.60 |
27.7 |
1255 |
1710 |
50 |
1.0 |
20.4 |
497 |
1100 |
18.7 |
1.60 |
25.8 |
1430 |
1800 |
70 |
1.1 |
23.1 |
690 |
1520 |
21.5 |
1.60 |
29.0 |
1780 |
2320 |
95 |
1.1 |
26.5 |
850 |
2050 |
24.6 |
2.00 |
31.1 |
1950 |
3150 |
120 |
1.2 |
28.4 |
1170 |
2610 |
26.8 |
2.00 |
36.1 |
2440 |
3880 |
150 |
1.4 |
31.7 |
1450 |
3220 |
29.7 |
2.00 |
39.3 |
3050 |
4820 |
185 |
1.6 |
35.1 |
1810 |
4030 |
33.3 |
2.50 |
44.7 |
3690 |
5920 |
240 |
1.7 |
40.3 |
2280 |
5200 |
38.1 |
2.50 |
49.0 |
4380 |
7300 |
300 |
1.8 |
44.3 |
2760 |
6430 |
42.3 |
2.50 |
53.5 |
5100 |
8770 |
|
STRANDED
COPPER & ALUMINIUM CONDUCTOR THREE CORE CABLES
XLPE Insulated Armoured
PVC Sheathed Cable to BS : 5467 & IEC :502(I) |
Nominal Area of Conductor Sq.mm |
Thickness of XLPE Insulationmm |
Cable Diameter Overallmm |
Cable Weight AluminiumKg/Km |
Cable Weight CopperKg/Km |
Diameter Under Armourmm |
Armour @ Wire Diametermm |
Cable Diameter Overallmm |
Cable Weight AluminiumKg/Km |
Cable Weight CopperKg/Km |
16 |
0.7 |
18.0 |
-- |
675 |
16.0 |
1.25 |
21.6 |
-- |
1130 |
25 |
0.9 |
21.5 |
500 |
990 |
20.0 |
1.6 |
26.7 |
1220 |
1710 |
35 |
0.9 |
24.0 |
610 |
1295 |
22.7 |
1.6 |
29.4 |
1415 |
2100 |
50 |
1.0 |
24.6 |
740 |
1640 |
23.0 |
1.6 |
28.5 |
1550 |
2450 |
70 |
1.1 |
28.0 |
1050 |
2220 |
26.0 |
1.6 |
32.2 |
1810 |
3120 |
95 |
1.1 |
31.0 |
1170 |
2980 |
30.0 |
2.0 |
37.0 |
2500 |
4310 |
120 |
1.2 |
34.8 |
1440 |
3730 |
32.8 |
2.0 |
40.4 |
2870 |
5160 |
150 |
1.4 |
38.5 |
2300 |
5195 |
36.8 |
2.5 |
45.5 |
3660 |
7160 |
185 |
1.6 |
44.0 |
2750 |
6470 |
41.5 |
2.5 |
49.8 |
4320 |
8600 |
240 |
1.7 |
49.5 |
3020 |
8380 |
46.0 |
2.5 |
55.1 |
5170 |
10555 |
300 |
1.8 |
53.5 |
3660 |
10420 |
51.5 |
2.5 |
60.2 |
6100 |
13080 |
400 |
2.0 |
59.2 |
3730 |
11575 |
56.4 |
2.5 |
66.6 |
7050 |
15810 |
|
STRANDED
COPPER & ALUMINIUM CONDUCTOR FOUR CORE CABLES
XLPE Insulated Armoured
PVC Sheathed Cable to BS : 5467 & IEC :502(I) |
Nominal Area of Conductor Sq.mm |
Thickness of XLPE Insulationmm |
Cable Diameter Overallmm |
Cable Weight AluminiumKg/Km |
Cable Weight CopperKg/Km |
Diameter Under Armourmm |
Armour @ Wire Diametermm |
Cable Diameter Overallmm |
Cable Weight AluminiumKg/Km |
Cable Weight CopperKg/Km |
16 |
0.7 |
20.0 |
--- |
780 |
18.0 |
1.25 |
23.4 |
-- |
1320 |
25 |
0.9 |
21.0 |
520 |
1160 |
20.0 |
1.6 |
26.1 |
1200 |
1840 |
35 |
0.9 |
24.5 |
650 |
1540 |
22.8 |
1.6 |
28.6 |
1420 |
2310 |
50 |
1.0 |
26.5 |
900 |
2100 |
25.5 |
1.6 |
32.0 |
1770 |
2970 |
70 |
1.1 |
31.0 |
1210 |
2950 |
29.5 |
2.0 |
37.7 |
2500 |
4240 |
95 |
1.1 |
35.2 |
1550 |
3970 |
33.5 |
2.0 |
41.7 |
2980 |
5400 |
120 |
1.2 |
39.0 |
1910 |
4960 |
37.5 |
2.5 |
47.1 |
3950 |
7000 |
150 |
1.4 |
43.5 |
2410 |
6160 |
41.5 |
2.5 |
51.4 |
4600 |
8350 |
185 |
1.6 |
49.0 |
2990 |
7690 |
46.0 |
2.5 |
56.6 |
5430 |
10130 |
240 |
1.7 |
54.5 |
3890 |
10070 |
52.5 |
2.5 |
63.0 |
6660 |
12840 |
300 |
1.8 |
61.0 |
4730 |
12490 |
57.5 |
2.5 |
68.8 |
7770 |
15530 |
400 |
2.0 |
67.5 |
5780 |
15620 |
65.0 |
3.15 |
78.1 |
10380 |
19950 |
500 |
2.2 |
74.2 |
7500 |
19900 |
72.6 |
3.15 |
82.0 |
12200 |
24360 |
|
STRANDED COPPER &
ALUMINIUM CONDUCTOR FOUR CORE CABLES WITH REDUCED NEUTRAL CONDUCTOR
XLPE Insulated Armoured
PVC Sheathed Cable to BS : 5467 & IEC :502(I) |
Nominal Area of Conductor Sq.mm |
Nominal Area of Neutral Sq.mm |
Thickness of XLPE Insulationmm |
Cable Diameter Overallmm |
Cable Weight AluminiumKg/Km |
Cable Weight CopperKg/Km |
Diameter Under Armourmm |
Armour @ Wire Diametermm |
Cable Diameter Overallmm |
Cable Weight AluminiumKg/Km |
Cable Weight CopperKg/Km |
25 |
16 |
0.9 |
21.4 |
--- |
1070 |
19.1 |
1.6 |
26.1 |
--- |
1750 |
35 |
16 |
0.9 |
23.2 |
--- |
1360 |
22.0 |
1.6 |
27.9 |
--- |
2130 |
50 |
25 |
1.0 |
26.1 |
860 |
1920 |
24.5 |
1.6 |
31.2 |
1710 |
2770 |
70 |
35 |
1.1 |
30.4 |
1080 |
2610 |
28.5 |
2.0 |
36.6 |
2340 |
3870 |
95 |
50 |
1.1 |
39.4 |
1390 |
3500 |
32.0 |
2.0 |
41.0 |
2800 |
4910 |
120 |
70 |
1.2 |
39.0 |
1820 |
4540 |
35.5 |
2.0 |
45.3 |
3340 |
6060 |
150 |
70 |
1.4 |
42.5 |
2190 |
5440 |
39.5 |
2.5 |
50.0 |
4360 |
7610 |
185 |
95 |
1.6 |
47.7 |
2630 |
6760 |
43.5 |
2.5 |
53.3 |
5020 |
9150 |
240 |
120 |
1.7 |
53.4 |
3500 |
8900 |
50.2 |
2.5 |
61.1 |
6220 |
11620 |
300 |
150 |
1.8 |
59.0 |
4240 |
11000 |
55.0 |
2.5 |
66.7 |
7220 |
13980 |
400 |
185 |
2.0 |
67.0 |
5560 |
13900 |
62.5 |
3.15 |
73.8 |
9950 |
18250 |
500 |
240 |
2.2 |
74.0 |
6700 |
17560 |
68.8 |
3.15 |
83.9 |
11200 |
22000 |
|
CURRENT
RATINGS (AC) - FOR BOTH BS:5467 & IEC; 502(I)
COPPER
AND ALUMINIUM CONDUCTOR - SINGLE CORE CABLES
1.
CORE, XLPE INSULATED ARMOURED / PVC SHEATHED CABLES - 600 / 1000 V
Nominal Area of Conductor
Sq.mm |
Stranded "CU" Conductors Current
Ratings (amps) |
|
Stranded "AL" Conductors Current
Ratings (amps) |
Direct in ground 30 c |
In Single way duct |
Installed in air 40c |
Direct in ground 30 c |
In Single way duct |
Installed in air 40c |
50 |
209 |
209 |
202 |
155 |
155 |
147 |
70 |
258 |
249 |
259 |
196 |
196 |
188 |
95 |
307 |
294 |
315 |
231 |
231 |
229 |
120 |
347 |
329 |
365 |
262 |
262 |
265 |
150 |
387 |
360 |
421 |
294 |
294 |
306 |
185 |
436 |
391 |
481 |
333 |
325 |
355 |
240 |
498 |
445 |
568 |
387 |
365 |
423 |
300 |
560 |
489 |
655 |
436 |
405 |
491 |
400 |
623 |
516 |
741 |
480 |
427 |
568 |
500 |
685 |
551 |
835 |
516 |
453 |
649 |
630 |
748 |
596 |
934 |
560 |
480 |
728 |
800 |
790 |
616 |
1018 |
635 |
540 |
880 |
1000 |
838 |
654 |
1104 |
705 |
600 |
1020 |
|
COPPER
AND ALUMINIUM CONDUCTOR - TWO CORE CABLES
2
CORE, XLPE INSULATED ARMOURED / PVC SHEATHED CABLES - 600 / 1000 V
Nominal Area of Conductor
Sq.mm |
Stranded "CU" Conductors Current
Ratings (amps) |
|
Stranded "AL" Conductors Current
Ratings (amps) |
Direct in ground 30 c |
In Single way duct |
Installed in air 40c |
Direct in ground 30 c |
In Single way duct |
Installed in air 40c |
16 |
124 |
102 |
104 |
83 |
69 |
74 |
25 |
160 |
124 |
138 |
120 |
98 |
101 |
35 |
191 |
151 |
171 |
146 |
115 |
125 |
50 |
227 |
182 |
207 |
173 |
138 |
151 |
70 |
280 |
227 |
264 |
213 |
173 |
192 |
95 |
339 |
276 |
322 |
253 |
210 |
231 |
120 |
365 |
306 |
391 |
283 |
230 |
263 |
150 |
420 |
341 |
436 |
322 |
250 |
300 |
185 |
479 |
384 |
491 |
363 |
286 |
344 |
240 |
566 |
448 |
573 |
407 |
327 |
406 |
300 |
651 |
498 |
637 |
445 |
363 |
456 |
400 |
-- |
-- |
-- |
458 |
411 |
525 |
500 |
-- |
-- |
-- |
522 |
467 |
597 |
630 |
-- |
-- |
-- |
590 |
529 |
676 |
|
CURRENT
RATINGS (AC) - FOR BOTH BS:5467 & IEC; 502(I)
COPPER
AND ALUMINIUM CONDUCTOR - (3C, 4C, & 31/2 C CABLES)
XLPE
INSULATED ARMOURED / PVC SHEATHED CABLES - 600 / 1000 V
Nominal Area of Conductor
Sq.mm |
Stranded "CU" Conductors Current
Ratings (amps) |
|
Stranded "AL" Conductors Current
Ratings (amps) |
Direct in ground 30°c |
In Single way duct |
Installed in air 40°c |
Direct in ground 30° c |
In Single way duct |
Installed in air 40°c |
16 |
102 |
83 |
90 |
79 |
64 |
67 |
25 |
133 |
111 |
119 |
102 |
83 |
89 |
35 |
160 |
133 |
147 |
120 |
97 |
109 |
50 |
191 |
155 |
179 |
146 |
120 |
131 |
70 |
235 |
191 |
228 |
178 |
146 |
168 |
95 |
280 |
231 |
276 |
213 |
178 |
203 |
120 |
320 |
267 |
321 |
244 |
204 |
240 |
150 |
360 |
298 |
369 |
275 |
226 |
277 |
185 |
409 |
338 |
421 |
311 |
262 |
318 |
240 |
471 |
391 |
496 |
364 |
302 |
380 |
300 |
525 |
440 |
571 |
409 |
342 |
444 |
400 |
593 |
507 |
662 |
462 |
394 |
511 |
500 |
-- |
-- |
-- |
500 |
465 |
630 |
630 |
-- |
-- |
-- |
|
560 |
520 |
710 |
|
Short
Circuit Rating - Conductors
Short Cicuit ratings for 1 second in KA |
Conductor size sq.mm |
Copper Conductor |
Aluminium Conductor |
1.5 |
0.21 |
0.14 |
2.5 |
0.36 |
0.24 |
4 |
0.57 |
0.38 |
6 |
0.86 |
0.56 |
10 |
1.43 |
0.94 |
16 |
2.29 |
1.50 |
25 |
3.58 |
2.35 |
35 |
5.00 |
3.29 |
50 |
7.15 |
4.70 |
70 |
10.01 |
6.58 |
95 |
13.59 |
8.93 |
120 |
17.16 |
11.28 |
150 |
21.45 |
14.10 |
185 |
26.46 |
17.39 |
240 |
34.32 |
22.56 |
300 |
42.90 |
28.20 |
400 |
57.20 |
37.60 |
630 |
90.09 |
59.22 |
800 |
114.40 |
75.20 |
1000 |
143.00 |
94.00 |
|
<< Back |